Designed for portability and durability, Topaz Portable Air Conditioners set up in minutes and their rugged design rolls easily from shop floor to indoor office areas. Seven models are available offering from 11,900 – 75,900 BTU/hr of cooling power. These newly redesigned units also offer total temperature control with digital, programmable thermostats and an electric heat option*.
TOPAZ Portable Air Conditioner Features:
![]() |
TOPAZ Is Ideal For:
|
*Not available on all models
![]()
Office Installation

Computer Room

Industrial Applications

| SPECIFICATIONS | TZ-12B | TZ-18B | TZ-24B | TZ-36B | TZ-60B | TZ-60B3 | TZ-60B4 |
|---|---|---|---|---|---|---|---|
| COOLING CAPACITY BTU/ HR¹ | 13,500 | 17,300 | 29,600 | 41,000 | 75,900 | 75,900 | 75,900 |
| POWER SUPPLY – VOLTS/PHASE/HERTZ/AMPS | 115/1/60/15 | 115/1/60/15 | 208-230/1/60/20 | 208-230/1/60/30 | 208-230/1/60/60 | 208-230/3/60/40 | 460/3/60/20 |
| THERMOSTAT CONTROL | MECHANICAL | DIGITAL | DIGITAL | DIGITAL | DIGITAL | DIGITAL | DIGITAL |
| METERING DEVICE | TX VALVE | TX VALVE | TX VALVE | TX VALVE | TX VALVE | TX VALVE | TX VALVE |
| POWER CONSUMPTION- COOLING, WATTS | 1,400 | 1,400 | 3,100 | 4,500 | 7,700 | 8,500 | 10,000 |
| CURRENT CONSUMPTION-COOLING, AMPS | 11.6 | 12.0 | 13.5 | 19.7 | 33.3 | 21.4 | 11.4 |
| RECOMMENDED CIRCUIT AMPS |
15 | 15 | 20 | 30 | 60 | 40 | 20 |
| MAXIMUM OVERCURRENT PROTECTIVE DEVICE, AMPS |
— | — | — | — | 80 | 50 | 25 |
| NEMA – PLUG TYPE |
5-15P | 5-15P | 6-20P | 6-30P | WIRED | WIRED | WIRED |
| EVAPORATOR CFM, FREE DISCHARGE |
350 | 550 | 750 | 1,200 | 2,300 | 2,300 | 2,300 |
| CONDENSER CFM |
500 | 1,000 | 1,000 | 1,500 | 3,900 | 3,900 | 3,900 |
| MAXIMUM ESP, inWC |
.10 | .10 | .10 | .10 | .50 | .50 | .50 |
| MAXIMUM DUCT LENGTH (FT) | 40 | 40 | 40 | 40 | 40 | 40 | 40 |
| CONDENSATE-PUMP HEAD (FT) |
15 | 15 | 15 | 15 | 15 | 15 | 15 |
| OPERATING LIMITS (MIN-MAX) ºF |
65-105 | 65-110 | 65-105 | 65-105 | 65-110 | 65-110 | 65-110 |
| SOUND LEVEL (DB) |
57 | 61 | 63 | 67 | 71 | 71 | 71 |
| R-410-A CHARGE (OZ) |
42 | 80 | 80 | 70 | 136 | 136 | 136 |
| L x W x H (INCHES) | 28x19x38 | 28x23x47 | 33x26x47 | 30x28x51 | 47x31x64 | 47x31x64 | 47x31x64 |
| WEIGHT – NET WT/SHIPPING WT (LBS) | 163/205 | 221/279 | 337/375 | 336/395 | 713/775 | 713/775 | 713/775 |
| 1. Rating Conditions: 95ºF at 60% RH. 2. Electrical Ratings based on UL484. |
|||||||
All Specifications are subject to change without notice.
| OPTIONAL ACCESSORIES | TZ-12B | TZ-18B | TZ-24B | TZ-36B | TZ-60B | TZ-60B3 | TZ-60B4 |
|---|---|---|---|---|---|---|---|
| NOZZLE KIT |
NK-1 (4″) | NK-2 (6″) | NK-2 (6″) | NK-2 (6″) | NK-3 (8″) | NK-3 (8″) | NK-3 (8″) |
| CEILING DISCHARGE KIT |
CK-1 (10″) | CK-3 (14″) | CK-3 (14″) | CK-3 (14″) | CK-4 (20″) | CK-4 (20″) | CK-4 (20″) |
| CONDENSATE PUMP |
PC-1 | PC-1 | PC-2 | PC-2 | Included | Included | Included |
| CONDENSER RETURN-AIR PLENUM |
CP-1B (10″) | CP-2B (14″) | CP-2B (14″) | CP-3 (14″) | CP-4B (20″) | CP-4B (20″) | CP-4B (20″) |
| EVAPORATOR RETURN-AIR PLENUM | EP-1B (10″) | EP-2B (14″) | EP-2B (14″) | EP-3 (14″) | EP-4B (20″) | EP-4B (20″) | EP-4B (20″) |
| COLD-AIR SUPPLY DUCT ADAPTER |
DA-6 | DA-10 | DA-10 | DA-10 | DA-14 | DA-14 | DA-14 |
| 14-60P PLUG KIT W/6′ CORD |
— | — | — | — | CD-60 | — | — |